「機器リスト」の版間の差分
ナビゲーションに移動
検索に移動
編集の要約なし |
編集の要約なし |
||
14行目: | 14行目: | ||
|ルータ | |ルータ | ||
|Ubiquiti | |Ubiquiti | ||
|ER-X | |[https://www.ui.com/edgemax/edgerouter-x/ ER-X] | ||
|2 | |2 | ||
|PPPoE | |PPPoE | ||
27行目: | 27行目: | ||
|仮想 ルータ | |仮想 ルータ | ||
|Cisco | |Cisco | ||
| | |[https://www.cisco.com/c/en/us/products/collateral/routers/catalyst-8000v-edge-software/datasheet-c78-744101.html C8000V] | ||
|2 | |2 | ||
|IPv6 | |IPv6 | ||
43行目: | 43行目: | ||
|コアスイッチ (L2) | |コアスイッチ (L2) | ||
|Juniper | |Juniper | ||
|EX2200-C-12T | |[https://www.juniper.net/content/dam/www/assets/datasheets/us/en/switches/ex2300-c-compact-ethernet-switch-datasheet.pdf EX2200-C-12T] | ||
|2 | |2 | ||
|仮想 Chassis | |仮想 Chassis | ||
50行目: | 50行目: | ||
|ファイアウォール | |ファイアウォール | ||
|Juniper | |Juniper | ||
|SRX210H-PoE | |[https://www.juniper.net/content/dam/www/assets/datasheets/us/en/security/srx-series-services-gateways-branch-datasheet.pdf SRX210H-PoE] | ||
|2 | |2 | ||
|BGP | |BGP | ||
60行目: | 60行目: | ||
|アクセス+管理 L2SW | |アクセス+管理 L2SW | ||
|Cisco | |Cisco | ||
|WS-C3750G-24T-E1U | |[https://www.cisco.com/web/JP/product/hs/switches/cat3750/prodlit/pdf/cat3750_cat2.pdf WS-C3750G-24T-E1U] | ||
|1 | |1 | ||
|BGP | |BGP | ||
74行目: | 74行目: | ||
|ワイヤレス アクセスポイント | |ワイヤレス アクセスポイント | ||
|Cisco | |Cisco | ||
|AIR-CAP1702I-Q-K9 | |[https://www.cisco.com/c/en/us/products/collateral/wireless/aironet-1700-series/datasheet-c78-732347.html AIR-CAP1702I-Q-K9] | ||
|1 | |1 | ||
|802.11ac | |802.11ac | ||
91行目: | 91行目: | ||
|ハイパーバイザ / ESXi7.0b | |ハイパーバイザ / ESXi7.0b | ||
|Lenovo | |Lenovo | ||
|ThinkCentre M900 | |[https://www.lenovo.com/jp/ja/static/catalog/dt-2015-m900tiny_cf_1117 ThinkCentre M900 Tiny] | ||
|2 | |2 | ||
|CPU : Intel Core i5-6500T 2.5Ghz 4 Core | |CPU : Intel Core i5-6500T 2.5Ghz 4 Core | ||
106行目: | 106行目: | ||
|NAS #1 , #2 | |NAS #1 , #2 | ||
|Synology | |Synology | ||
|DS216j | |[https://global.download.synology.com/download/Document/Hardware/DataSheet/DiskStation/16-year/DS216j/jpn/Synology_DS216j_Data_Sheet_jpn.pdf DS216j] | ||
|2 | |2 | ||
|HDD : HGST 8TB 0S04012 x2 RAID0 | |HDD : HGST 8TB 0S04012 x2 RAID0 | ||
115行目: | 115行目: | ||
|PDU | |PDU | ||
|APC | |APC | ||
|AP7900 | |[https://www.apc.com/shop/jp/ja/products/Rack-PDU-Switched-1U-15A-100-120V-8-5-15/P-AP7900 AP7900] | ||
|2 | |2 | ||
| - | | - | ||
123行目: | 123行目: | ||
|UPS | |UPS | ||
|Omron | |Omron | ||
|BY50S | |[https://socialsolution.omron.com/jp/ja/products_service/ups/product/by35-120s/by35-120s.html BY50S] | ||
|2 | |2 | ||
|210W 6 分 | |210W 6 分 | ||
130行目: | 130行目: | ||
< | <span></span><ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-1930311742297749" data-ad-slot="5409634032"></ins><span></span><span></span> | ||
== 東日本 == | == 東日本 == | ||
145行目: | 145行目: | ||
|ルータ | |ルータ | ||
|Ubiquiti | |Ubiquiti | ||
|ER-X | |[https://www.ui.com/edgemax/edgerouter-x/ ER-X] | ||
|2 | |2 | ||
|DHCP | |DHCP | ||
158行目: | 158行目: | ||
|ワイヤレス ルータ | |ワイヤレス ルータ | ||
|NEC | |NEC | ||
|Aterm PA-HT100LN-SW | |[https://www.aterm.jp/product/atermstation/product/mobile/ht100ln/ Aterm PA-HT100LN-SW] | ||
|1 | |1 | ||
|LTE | |LTE | ||
166行目: | 166行目: | ||
|仮想 ルータ | |仮想 ルータ | ||
|Cisco | |Cisco | ||
| | |[https://www.cisco.com/c/en/us/products/collateral/routers/catalyst-8000v-edge-software/datasheet-c78-744101.html C8000V] | ||
|2 | |2 | ||
|IPv6 | |IPv6 | ||
182行目: | 182行目: | ||
|コアスイッチ (L3) | |コアスイッチ (L3) | ||
|Cisco | |Cisco | ||
|WS- | |[https://www.cisco.com/c/ja_jp/products/collateral/switches/catalyst-3560-cx-series-switches/datasheet-c78-733229.html WS-C3560CX-8XPD-S] | ||
|2 | |2 | ||
|BGP | |BGP | ||
194行目: | 194行目: | ||
|アクセス+管理 L3SW | |アクセス+管理 L3SW | ||
|Cisco | |Cisco | ||
|WS-C3750G-24T-E1U | |[https://www.cisco.com/web/JP/product/hs/switches/cat3750/prodlit/pdf/cat3750_cat2.pdf WS-C3750G-24T-E1U] | ||
|2 | |2 | ||
|StackWise | |StackWise | ||
204行目: | 204行目: | ||
|ワイヤレス アクセスポイント | |ワイヤレス アクセスポイント | ||
|Cisco | |Cisco | ||
|AIR-CAP2702I-Q-K9 | |[https://www.cisco.com/c/en/us/products/collateral/wireless/aironet-2700-series-access-point/datasheet-c78-730593.html AIR-CAP2702I-Q-K9] | ||
|1 | |1 | ||
|802.11ac | |802.11ac | ||
211行目: | 211行目: | ||
|コンソール サーバ | |コンソール サーバ | ||
|Digi CM | |Digi CM | ||
|CM-48 | |[https://hub.digi.com/support/products/infrastructure-management/digi-cm/ CM-48] | ||
| | | | ||
| - | | - | ||
|Web GUI 付きコンソール サーバ | |Web GUI 付きコンソール サーバ | ||
|- | |||
|トラフィック ジェネレータ | |||
|Data Controls | |||
|[https://www.dci.jp/2009/06/nudog301.html NuDOG-301] | |||
|1 | |||
|SFP / RJ-45 1G x2 | |||
| | |||
|} | |} | ||
226行目: | 233行目: | ||
!用途 | !用途 | ||
|- | |- | ||
|ハイパーバイザ / ESXi7.0b | | rowspan="2" |非 常時稼働ハイパフォーマンスサーバ | ||
ハイパーバイザ / ESXi7.0b | |||
|Silver Stone | |Silver Stone | ||
|[https://www.silverstonetek.com/product.php?pid=488&area=jp SST-GD09B] | |||
|SST-GD09B | |1 | ||
X9DRL-iF | |ATX SSI-CEB 対応 デスクトップ ケース | ||
| | |||
|- | |||
|SuperMicro | |||
|[https://www.supermicro.com/products/motherboard/xeon/c600/x9drl-if.cfm X9DRL-iF] | |||
|1 | |1 | ||
|CPU : Intel Xeon 2690v2 3.0Ghz 10 Core x2 | |CPU : Intel Xeon 2690v2 3.0Ghz 10 Core x2 | ||
245行目: | 257行目: | ||
* EVE-NG (メモリが大量に必要な検証用) | * EVE-NG (メモリが大量に必要な検証用) | ||
|- | |- | ||
|ハイパーバイザ / ESXi6.7 | |常時稼働省電力・静音サーバ | ||
ハイパーバイザ / ESXi6.7 | |||
|Supermicro | |Supermicro | ||
|E300-9A | |[https://www.supermicro.com/ja/products/system/Mini-ITX/SYS-E300-9A.cfm E300-9A] | ||
|1 | |1 | ||
|CPU : Intel Atom C3858 2.0Ghz 12 Core | |CPU : Intel Atom C3858 2.0Ghz 12 Core | ||
265行目: | 278行目: | ||
|NAS #1 | |NAS #1 | ||
|Synology | |Synology | ||
|DS1618+ | |[https://global.download.synology.com/download/Document/Hardware/DataSheet/DiskStation/18-year/DS1618+/jpn/Synology_DS1618_Plus_Data_Sheet_jpn.pdf DS1618+] | ||
|1 | |1 | ||
|HDD : HGST 4TB 0S03361 x4 SHR | |HDD : HGST 4TB 0S03361 x4 SHR | ||
275行目: | 288行目: | ||
|NAS #2 | |NAS #2 | ||
|Synology | |Synology | ||
|DS216j | |[https://global.download.synology.com/download/Document/Hardware/DataSheet/DiskStation/16-year/DS216j/jpn/Synology_DS216j_Data_Sheet_jpn.pdf DS216j] | ||
|1 | |1 | ||
|HDD : HGST 8TB 0S04012 x2 RAID0 | |HDD : HGST 8TB 0S04012 x2 RAID0 | ||
283行目: | 296行目: | ||
|PDU | |PDU | ||
|APC | |APC | ||
|AP7900 | |[https://www.apc.com/shop/jp/ja/products/Rack-PDU-Switched-1U-15A-100-120V-8-5-15/P-AP7900 AP7900] | ||
|2 | |2 | ||
| - | | - | ||
|Web GUI 付き インテリジェント PDU | |Web GUI 付き インテリジェント PDU | ||
各機器をリモートから電源 off / on | 各機器をリモートから電源 off / on | ||
|} | |} | ||
< | <span></span><ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-1930311742297749" data-ad-slot="5409634032"></ins><span></span><span></span> | ||
{{#seo: | {{#seo: |
2021年12月5日 (日) 17:33時点における版
hkatou Lab で使用している機器のリストです。
西日本
ネットワーク
種類 | メーカー | 名称・型式 | 台数 | プロトコル・規格 | 用途 |
---|---|---|---|---|---|
ルータ | Ubiquiti | ER-X | 2 | PPPoE
NAT IPsec VPN BGP RR |
WAN 回線収容
拠点間ルーティング |
仮想 ルータ | Cisco | C8000V | 2 | IPv6
FlexVPN EVPN (L2VPN/L3VPN) BGP MPLS OSPFv2 |
緊急メンテナンス用 IPv6 VPN ルータ |
コアスイッチ (L2) | Juniper | EX2200-C-12T | 2 | 仮想 Chassis | 冗長化対応スイッチ |
ファイアウォール | Juniper | SRX210H-PoE | 2 | BGP
OSPFv2 OSPFv3 |
サーバ用ファイアウォール |
アクセス+管理 L2SW | Cisco | WS-C3750G-24T-E1U | 1 | BGP
OSPFv2 OSPFv3 IPoE DHCPv6-PD |
IPv6 GW ルータ 兼 管理 L2SW |
ワイヤレス アクセスポイント | Cisco | AIR-CAP1702I-Q-K9 | 1 | 802.11ac | Autonomous モード |
サーバ
種類 | メーカー | 名称・型式 | 台数 | スペック | 用途 |
---|---|---|---|---|---|
ハイパーバイザ / ESXi7.0b | Lenovo | ThinkCentre M900 Tiny | 2 | CPU : Intel Core i5-6500T 2.5Ghz 4 Core
Memory : Crucial DDR4 16GB x2 SSD : Crucial MX500 1TB Management : Intel vPro |
VM
|
NAS #1 , #2 | Synology | DS216j | 2 | HDD : HGST 8TB 0S04012 x2 RAID0
NIC : 1G x1 |
#1 : East NAS#1 と自動同期
#2 : #1 のバックアップ |
PDU | APC | AP7900 | 2 | - | Web GUI 付き インテリジェント PDU
各機器をリモートから電源 off / on |
UPS | Omron | BY50S | 2 | 210W 6 分 |
東日本
ネットワーク
種類 | メーカー | 名称・型式 | 台数 | プロトコル・規格 | 用途 |
---|---|---|---|---|---|
ルータ | Ubiquiti | ER-X | 2 | DHCP
NAT IPsec VPN BGP RR |
WAN 回線収容
拠点間ルーティング |
ワイヤレス ルータ | NEC | Aterm PA-HT100LN-SW | 1 | LTE
802.11ac |
LTE 回線 IPv6 終端ルータ |
仮想 ルータ | Cisco | C8000V | 2 | IPv6
FlexVPN EVPN (L2VPN/L3VPN) BGP MPLS OSPFv2 |
緊急メンテナンス用 IPv6 VPN ルータ |
コアスイッチ (L3) | Cisco | WS-C3560CX-8XPD-S | 2 | BGP
OSPFv2 OSPFv3 HSRP |
10G 冗長化対応スイッチ |
アクセス+管理 L3SW | Cisco | WS-C3750G-24T-E1U | 2 | StackWise
BGP OSPFv2 |
アクセス層 L3SW 兼 管理 L2SW |
ワイヤレス アクセスポイント | Cisco | AIR-CAP2702I-Q-K9 | 1 | 802.11ac | Autonomous モード |
コンソール サーバ | Digi CM | CM-48 | - | Web GUI 付きコンソール サーバ | |
トラフィック ジェネレータ | Data Controls | NuDOG-301 | 1 | SFP / RJ-45 1G x2 |
サーバ
種類 | メーカー | 名称・型式 | 台数 | スペック | 用途 |
---|---|---|---|---|---|
非 常時稼働ハイパフォーマンスサーバ
ハイパーバイザ / ESXi7.0b |
Silver Stone | SST-GD09B | 1 | ATX SSI-CEB 対応 デスクトップ ケース | |
SuperMicro | X9DRL-iF | 1 | CPU : Intel Xeon 2690v2 3.0Ghz 10 Core x2
Memory : DDR4 ECC Reg 16GB x 8 SSD : Crucial MX500 1TB Management : Supermicro IPMI Network : 10G x2 , 1G x2 |
非 常時稼働
VM
| |
常時稼働省電力・静音サーバ
ハイパーバイザ / ESXi6.7 |
Supermicro | E300-9A | 1 | CPU : Intel Atom C3858 2.0Ghz 12 Core
Memory : DDR4 SO-DIMM 16GB x 4 SSD : Crucial MX500 1TB Management : Supermicro IPMI Network : 10G x2 , 10G-T x2 , 1G x4 |
VM
|
NAS #1 | Synology | DS1618+ | 1 | HDD : HGST 4TB 0S03361 x4 SHR
SSD : Crucial SSD 512MB x2 キャッシュ用 NIC : 10G x2 , 1G x4 |
10G 対応 SMB / TFTP / FTP / NFS サーバ |
NAS #2 | Synology | DS216j | 1 | HDD : HGST 8TB 0S04012 x2 RAID0
NIC : 1G x1 |
#2 : #1 のバックアップ |
PDU | APC | AP7900 | 2 | - | Web GUI 付き インテリジェント PDU
各機器をリモートから電源 off / on |